fbpx

Regulatory Compliance and Flight Restricted Area

Compliance and Advisory

FCC Warning Message

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Radiation Exposure Statement

For EVO Series / EVO

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

For EVO Series with model EF7, SAR tests are conducted using standard operating positions accepted by the FCC/ISEDC with the device. When used, please keep the distance with a minimum of 10mm from the body.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help.

ISEDC RSS warning

This device complies with ISEDC licence-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.

L’exploitation est autorisée aux deux conditions suivantes:

(1) l’appareil ne doit pas produire de brouillage, et

(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

ISEDC Radiation Exposure Statement

For EVO Series / EVO

This equipment complies with ISEDC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

For EVO Series with model EF7, SAR tests are conducted using standard operating positions accepted by the FCC/ISEDC with the device. when used, please keep the distance with a minimum of 10mm from the body.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Flight Restricted Area Illustration

The EVO system automatically recognizes the Flight Restricted Area, in which flights are limited by default. This feature guarantees pilots’ safe and legal operations of the product. The flight restricted areas are divided into 2 protection categories.

Flight restrictions are enforced only within countries which require manufacturer restrictions by law. Currently only the country China requires manufactures to enforce flight restrictions.


 NOTE

The pilot is responsible to ensure they are following all flight rules and regulations in the areas they fly.


Category I: Major airports and flight areas where drones operate at low altitudes

• Take-off Restricted Zones (No-Fly Zones)

These areas are set within 2.4km (based on country imposed rules) around the midway point of specified locations.

• Altitude Restricted Zones

In these areas, the aircraft is only allowed to fly within limited altitudes. From 8km to 2.4km (based on country imposed rules) around the locations midway point, the flight altitude decreases progressively from 120m to 10.5m.

• Warning Zones

Once the aircraft enters a region within 8.1 km from the central point of the airport, the app will prompt a warning message.


 NOTE

The aircraft will land automatically when entering any Take-off Restricted Zones. If the aircraft enters any Altitude Restricted Zones, its maximum allowable altitude will be reduced accordingly. Pay special attention to the warning messages displayed on your app.


Category II: Sensitive areas and institutes such as military sites and border lines between countries

Take-off Restricted Zones (No-Fly Zones)

These areas are set within 1km around the center of the specified sites where takeoff and flight are prohibited.

Warning Zone

Once the aircraft enters the region within 2km from the center of the site, the app will prompt a warning message.